VPL UPVC SWR Drainage System is an easy & economical product for drainage of soil waste & rain water application in residential, commercial & industrial buildings conforming to IS: 13592 & the Fittings conforming to ISI: 14375-99, with many advantages over the conventional piping systems.
uPVC SWR Drainage System offers a maintenance-free solution for a longer service life with respect other systems.
SWR
PIPES & FITTINGS
UPVC SWR systems include an extensive range of Soil, Waste and Rain Water system for commercial, industrial, housing and public sector developments. VPL SWR systems can be joined by Solvent Cement (Permanent type) and as well as grooved Elastomeric sealing ring joint(Detachable) for soil, waste and rain water drainage Systems
KEY FEATURES
- Light in weight
- Resistant to corrosion
- Easy to install with leak proof joints.
- Available in 3/6 Mtrs lengths, with Plain/ Socket ended pipes.
APPLICATIONS
- Waste Water management systems;
- Piping for soil discharge
- Waste discharge
- Venting of gases
- Non pressure industrial drainage application (based on chemical compatibility)
- Rain water Harvesting.
- Available in sizes 40mm to 160 mm OD
VPL SWR PIPES CONFORMS TO IS 13592
DIMENSIONAL CHART OF PVC-U PIPES FOR SOIL AND WASTE DISCHARGE SYSTEM FOR INSIDE AND OUT SIDE BUILDINGS INCLUDING VENTILATION AND RAIN WATER SYSTEM PER IS: 13592 – 1992.
ALL DIMENSIONS ARE IN "mm"
Nominal Outside Diameter | Mean Outside Diameter | Out Side Diameter of pipe at Any point | Wall Thickness Type A | Wall Thickness Type B | ||||
Min | Max | Min | Max | Min | Max | Min | Max | |
(Clause – 7.1) | ||||||||
40 | 40 | 40.3 | 39.5 | 40.5 | 1.8 | 2.2 | 3.2 | 3.8 |
50 | 50 | 50.3 | 49.4 | 50.6 | 1.8 | 2.2 | 3.2 | 3.8 |
63 | 63 | 63.3 | 62.2 | 63.8 | 1.8 | 2.2 | 3.2 | 3.8 |
75 | 75 | 75.3 | 74.1 | 75.9 | 1.8 | 2.2 | 3.2 | 3.8 |
90 | 90 | 90.3 | 88.9 | 91.1 | 1.9 | 2.3 | 3.2 | 3.8 |
110 | 110 | 110.4 | 108.6 | 111.4 | 2.2 | 2.7 | 3.2 | 3.8 |
125 | 125 | 125.4 | 123.5 | 126.5 | 2.5 | 3 | 3.2 | 3.8 |
140 | 140 | 140.5 | 138.3 | 141.7 | 2.9 | 3.4 | 3.6 | 4.2 |
160 | 160 | 160.5 | 158 | 162 | 3.2 | 3.8 | 4 | 4.6 |
Product specifications and Pipes range are available in 40 to 160 mm and Fittings are available for all sizes. Pipes conform to IS 13592:92 and Fittings conform to IS 14375 and are made as per international standards as well. uPVC SWR Drainage System is available in – Yellow PP Rubber ring type joints -Leak proof Joints.
SWR DRAINAGE SYSTEM
| DO’S | DON’TS | |
![]() | CUTTING It is imperative to mark the pipe from all sides so that pipe is cut with the help of a Hand Saw. It should be a right angle cut from all the sides, The cut piece should not be with burr on edges | CUTTING
|
![]() | CHAMFERING After cutting the pipe needs to be chamfered from the outer sides. It is advisable to provide approximately 2mm wide, slight chamfer on spigot end of the pipe into the socket of the fitting. | CHAMFERING
|
![]() | DEBURRING AND RIDEGE REMOVAL Remove all the burrs and ridges accumulated on the inner as well as the outer edges of the pipe with the help of a deburring knife, file or abrasive paper | DEBURRING AND RIDEGE REMOVAL
|
![]() | DRYFIT TEST Before applying solvent cement, insert the pipe end into the socket of the next pipe end into the socket of the next pipe or fitting to check that interference occurs at about 1/3 to 2/3 of the socket depth. | DRYFIT TEST
|
![]() | CLEANING Thoroughly clean the pipe with dry cloth where the solvent cement is going to be applied to avoid dust, dirt, oil, moisture and other foreign material during the installation process | CLEANING
|
![]() | APPLICATION OF SOLVENT CEMENT Mark the pipe length to be inserted for jointing. Apply a liberal coat of solvent cement with the help of the brush on the marked surface | APPLICATION OF SOLVENT CEMENT
|
![]() | JOINTING Push the pipe inside the fitting/ pipe so that it goes inside equally from all the sides. Wipe off excess solvent cement that comes out of the edges. Hold the joint for one to two minutes so that the jointing is perfect. FOR THREADED JOINTS • Clean the Male & Female threads. • Apply Teflon tape in the direction of thread tightening Hand tighten the threads firmly • Tighten the joint more by using pipe wrench • Do not over tighten. Scrubber packing to avoid scratches on pipe | JOINTING FOR THREADED JOINTS
|






